Poplars Pumping Station

Poplars Pumping Station

Constructed in 1979 s part of the North Level Major Improvement Scheme. It was designed to evacuate surplus water from an area of 1119 hectares of predominantly agricultural land, but there are approximately 150 houses that benefit from the protection given by the pumping station.

Poplars Pumping Station consists of two 500mm diameter axial flow Weir pumps, each with a capacity of 46 T/min or 0.8 cumecs, both powered by 45 kw Brush Compton Electric Motors. The pumps and electric motors are of all weather construction, the electrical control switchgear being housed in a purpose built brick building. The pumps discharge directly into the North Level Main Drain via twin steel pipelines some 10m long.

Go to the Catchment and Pumping Stations map.

North Level District Internal Drainage Board
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.